- Skylla-IP44 (1+1): two outputs to charge 2 battery banks: The Skylla-IP44 (1+1) features 2 isolated outputs. The second output, limited to approximately 3 A and with a slightly lower output voltage, is intended to top up a starter battery.
- Skylla -IP44 (3): three full current outputs to charge 3 battery banks: The Skylla-IP44 (3) features 3 isolated outputs. All outputs can supply the full rated output current.
- IP44 protection: Steel epoxy powder coated case and splash proof. Withstands the rigors of an adverse environment: heat, humidity and salt air
- Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.
- LCD display: For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use.
- CAN bus interface (NMEA2000): To connect to a CAN bus network, to a Skylla-i Control panel or to the Color Control digital display.
- Synchronised parallel operation: Several chargers can be connected in parallel and synchronised with help of the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables.
- The right amount of charge for a lead-acid battery: variable absorption time: When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged.
- Preventing damage due to excessive gassing: the BatterySafe mode: If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla -IP44 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached.
- Less maintenance and aging when the battery is not in use: the Storage mode: The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2V/cell (26,4V for 24V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorptionlevel to refresh the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early
battery failure.
- To increase battery life: temperature compensation: Every Skylla-IP44comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected.
- Battery voltage sense: In order to compensate for voltage loss due to cable resistance, the Skylla-IP44is provided with a voltage sense facility so that the battery always receives the correct charge voltage.
- Use as a power supply: As a result of the excellent control circuit, the Skylla-IP44can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available.
- Li-Ion (LiFePO4) ready: Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN bus port.
Specifications:
- Input voltage (VAC): 120/230 V
- Input voltage range (VAC): 90-265V
- Maximum AC input current @ 100 VAC: 10A
- Frequency): 45-65 Hz
- Power factor: 0,98
- Charge voltage absorption(1): 28,8 V
- Charge voltage float: 27,6 V
- Charge voltage storage: 26,4 V
- Charge current (2): 3x 60A(max total output: 30 A
- Charge current starter batt. (A): 3 A
- Charge algorithm: 7 stage adaptive
- Battery capacity: 150-300 Ah
- Charge algorithm, Li-Ion: 3 stage, with on-off control or CAN bus control
- Temperature sensor: Yes
- Can be used as power supply: Yes
- Remote on-off por: Yes (can be connected to a Li-Ion BMS)
- CAN bus communication port(VE.Can): Two RJ45 connectors, NMEA2000 protocol, not isolated.
- Synchronised parallel operation: Yes, with VE.Can
- Alarm relay: DPST AC rating: 240VAC/4A DC rating: 4A up to 35VDC, 1A up to 60VDC
- Forced cooling: Yes(internal air circulation)
- Protection: Battery reverse polarity (fuse) Output short circuit Over temperature
- Operating temp. range: 20 to 60°C (Full output current up to 40°C)
- Humidity (non-condensing): max 95%
- Material: steel
- Battery-connection: M6bolts
- 230 VAC-connection: screw-clamp 6mm² (AWG 10)
- Protection category: IP44
- Weight: 6kg (14lbs)
- Dimensions (hxwxd) :
- 401 x 375x 265 mm
- 16x 15x 10.5 inch
Do not wait any longer and buy Victron energy Skylla IP44 24/30 with the best sending conditions and at the best price. In addition, at waveinn you can find other Chargers products in the Electronics category that can complement your order. Buy Victron energy Skylla IP44 24/30 and receive it as soon as possible. Have a look on our Electronics deals and choose our best offers.
Write a review about this product and earn CoINNs
Write a review about this product
Tradeinn Retail Services as the data controller will process your data in order to respond to your query or request. You can access, rectify and delete your data, as well as exercise other rights by consulting the additional and detailed information on data protection in our Privacy Policy.
30-DAY
EASY & FAST RETURN
SECURE & SAFE
SHOPPING
SATISFACTION
100% GUARANTEED
LOWEST PRICES
GUARANTEED
Related products